Hydraulic Butterfly Valve Test Bench of Model YFS-DL Series
Model:YFS-DL Series
Testing Range:DN50-3200(2"-128")
Testing Medium:Water,Air or Oil
1. Summary
The hydraulic butterfly valve test benches of model YFS-DL series are used to perform shell test and seat test on butterfly valves. The machines are in structure of vertical type. As for the way of loading and clamping of the valve to be tested, the test bench adopts the way of pulling downwards of the clamping jaw. As for the form of configuration, the test bench can also be designed into two types, single type, that is, one hydraulic station controls one workbench, and combined type, that is, one hydraulic station controls two workbenches. The appropriate type of test bench will be selected, designed and manufactured according to the customers′ requirements of valve testing size and pressure range.
2. Technical Parameters
Model & Specification | Type | Testing Range | Diameter & Quantity of Clamping Oil Cylinder | Spacing Between Jaw & Working Plate(mm) | Max.Clamping Force(Tons) | Motor of Oil Pump(6 Poles) |
Outine Dimensions(L×W×H) |
YFS-DL200 | Unitary | DN50-200 | φ100×3 | 200-400 | 50 | 2.2KW | 1000×2000×1600 |
YFS-DL300 | Unitary | DN80-300 | φ110×3 | 220-470 | 60 | 2.2KW | 1100×2100×1600 |
YFS-DL400 | Unitary | DN150-400 | φ120×4 | 260-540 | 90 | 3.0KW | 1180×2200×1600 |
YFS-DL500 | Unitary | DN200-500 | φ140×4 | 290-590 | 130 | 3.0KW | 1250×2300×1600 |
YFS-DL600 | Unitary | DN250-600 | φ150×4 | 310-630 | 150 | 3.0KW | 1350×2500×1600 |
YFS-DL800 | Unitary | DN350-800 | φ160×4 | 340-730 | 170 | 5.5KW | 1500×2800×1600 |
YFS-DL1000 | Unitary | DN500-1000 | φ160×6 | 380-880 | 250 | 5.5KW | 1800×3000×1700 |
YFS-DL1200 | Separate | DN600-1200 | φ180×6 | 410-960 | 350 | 5.5KW | 2100×3400×1700 |
YFS-DL1600 | Separate | DN800-1600 | φ200×6 | 550-1200 | 420 | 5.5KW | 2600×4000×1700 |
YFS-DL2000 |
Separate |
DN1000-2000 |
φ250×6 |
650-1250 |
650 |
7.5KW |
Design according to user requirements |
YFS-DL2400 |
Separate |
DN1400-2400 |
φ320×6 |
800-1500 |
1000 |
7.5KW |
Design according to user requirements |
YFS-DL2800 |
Separate |
DN1800-2800 |
φ360×6 |
1000-1750 |
1300 |
11.0KW |
Design according to user requirements |
YFS-DL3200 |
Separate |
DN2200-3200 |
φ420×6 |
1200-2000 |
1800 |
11.0KW |
Design according to user requirements |
3. Valve Test Ranges(Pressure Check Lists)
Model YFS-DL200
Nominal Diameter | Nominal Pressure MPa/class | ||||||||||
1.0
|
1.6
|
2.5
|
4.0
|
6.4
|
|||||||
|
|
150
|
300
|
400
|
|||||||
Pressure of Hydraulic Station
|
|||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
2″ | DN50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
21/2″ | DN65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
3″ | DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4″ | DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
5″ | DN125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
6″ | DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ | DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test;PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL300
Nominal Diameter |
Nominal Pressure MPa/class
|
||||||||||
1.0
|
1.6
|
2.5
|
4.0
|
6.4
|
|||||||
|
|
150
|
300
|
400
|
|||||||
Pressure of Hydraulic Station
|
|||||||||||
in | mm |
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
3″ | DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4″ | DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
5″ | DN125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
6″ | DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ | DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ | DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
||
12″ | DN300 |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL400
Nominal Diameter | Nominal Pressure MPa/class | ||||||||||||
0.6
|
1.0
|
1.6
|
2.5
|
4.0
|
6.4
|
||||||||
|
|
|
150
|
300
|
400
|
||||||||
Pressure of Hydraulic Station
|
|||||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
6″ | DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ | DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ | DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ | DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
14″ | DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
16″ | DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL500
Nominal Diameter | Nominal Pressure MPa/class | ||||||||||||
0.6
|
1.0
|
1.6
|
2.5
|
4.0
|
6.4
|
||||||||
|
|
|
150
|
300
|
400
|
||||||||
Pressure of Hydraulic Station
|
|||||||||||||
in | mm |
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
PN
|
PS
|
PN
|
PS |
8″ | DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ | DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ | DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
14″ | DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
16″ | DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
18″ | DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
||||
20″ | DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL600
Nominal Diameter |
Nominal Pressure MPa/class |
||||||||||||
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
||||||||
150 |
300 |
400 |
|||||||||||
Pressure of Hydraulic Station |
|||||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
10″ | DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ | DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
14″ | DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
16″ | DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
18″ | DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
20″ | DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
||||
24″ | DN600 |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL800
Nominal Diameter | Nominal Pressure MPa/class | ||||||||||
0.6 | 1.0 | 1.6 | 2.5 | 4.0 | |||||||
150 | 300 | ||||||||||
Pressure of Hydraulic Station | |||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
14″ | DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
16″ | DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
18″ | DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
20″ | DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
||
24″ | DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
||
28″ | DN700 |
● |
● |
● |
● |
● |
● |
||||
32″ | DN800 |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL1000
Nominal Diameter | Nominal Pressure MPa/class | ||||||||||
0.6 | 1.0 | 1.6 | 2.5 | 4.0 | |||||||
150 | 300 | ||||||||||
Pressure of Hydraulic Station | |||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
20″ | DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
24″ | DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
28″ | DN700 |
● |
● |
● |
● |
● |
● |
● |
● |
||
32″ | DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
||
36″ | DN900 |
● |
● |
● |
● |
● |
● |
||||
40″ | DN1000 |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL1200
Nominal Diameter |
Nominal Pressure MPa/class
|
||||||||||
0.6
|
1.0
|
1.6
|
2.5
|
4.0
|
|||||||
|
|
|
150
|
300
|
|||||||
Pressure of Hydraulic Station
|
|||||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
24″ | DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
28″ | DN700 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
32″ | DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
||
36″ | DN900 |
● |
● |
● |
● |
● |
● |
● |
● |
||
40″ | DN1000 |
● |
● |
● |
● |
● |
● |
||||
48″ | DN1200 |
● |
● |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-DL1600
Nominal Diameter | Nominal Pressure MPa/class | ||||||||
0.6 | 1.0 | 1.6 | 2.5 | ||||||
150 | |||||||||
Pressure of Hydraulic Station | |||||||||
in | mm | PN | PS | PN | PS | PN | PS | PN | PS |
32″ | DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
36″ | DN900 |
● |
● |
● |
● |
● |
● |
● |
● |
40″ | DN1000 |
● |
● |
● |
● |
● |
● |
● |
● |
48″ | DN1200 |
● |
● |
● |
● |
● |
● |
||
56″ | DN1400 |
● |
● |
● |
● |
||||
64″ | DN1600 |
● |
● |
● |
● |
Note: PN-denotes the pressure of the oil cylinder when performing seat test; PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Welcome to our website! Please send your words at any time in the following form and ask us, we will contact you and provide you with the corresponding service as soon as possible. Please write in English.
Model:PZ Series (Screw type)
Testing Range:DN15-1800 (1/2"-72") valve test by internal sealing way
Testing Medium:Water,Air or Oil
Model:YFS-L50t/100t Series
Testing Range:Press sealing rings of valves DN50-1200
Model: YFS-Z Series
Testing Range:DN15-1000(1/2"-40")
Testing Medium:Water,Air or Oil