Hydraulic Valve Test Bench of Model YFS-L Series(Vertical type)
Model:YFS-L Series
Testing Range:DN15-300(1/2"-12")
Testing Medium:Water,Air or Oil
1. Summary
The hydraulic valve test benches of model YFS-L series are used to perform shell test and seat test on flanged end valves, welded end valves, socket welded end valves and threaded end valves with size below DN300(12"), such as ball, gate, globe and check valves etc., adopting the way of jaw clamping on the bottom and thrust oil cylinder clamping on the top. The test benches of this model are wide in use, easy in operation,and high in working efficiency.
2. Technical Parameters
|
Model&
Specification
|
TestingRange | Diameter & Quantity of Bottom Clamping Oil Cylinders |
Diameter &Quantity of Top Thrust Oil Cylinder |
Max.Clamping Force (Tons) | Motor of Oil Pump |
Outline Dimensions(L×W×H) |
| YFS-L100 | DN15-100 | φ80×3 | φ120×1 | 30 | 2.2KW | 1710×700×1680mm |
| YFS-L200 | DN50-200 | φ100×3 | φ150×1 | 50 | 2.2KW | 1800×700×1780mm |
3. Pressure Check List
Model YFS-L100
| Nominal Diameter |
Nominal Pressure MPa/class |
||||||||||||||||||
|
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
|
Pressure of Hydraulic Station |
|||||||||||||||||||
| in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
| 1/2″ | DN15 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 3/4″ | DN20 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 1″ | DN25 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 11/4″ | DN32 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 11/2″ | DN40 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 2″ | DN50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 21/2″ | DN65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
| 3″ | DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||
| 4″ | DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||
Note: PN-denotes the pressure of the oil cylinder when performing seat test;PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Model YFS-L200
| Nominal Diameter |
Nominal Pressure MPa/class |
||||||||||||||||||
| 1.6 | 2.5 | 4.0 | 6.4 | 10.0 | 16.0 | 20.0 | 25.0 | 32.0 | |||||||||||
| 150 | 300 | 400 | 600 | 900 | 1500 | ||||||||||||||
|
Pressure of Hydraulic Station |
|||||||||||||||||||
| in | mm | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS | PN | PS |
| 2″ | DN50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 21/2″ | DN65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 3″ | DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| 4″ | DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||
| 5″ | DN125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||||
| 6″ | DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||
| 8″ | DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||||
Note: PN-denotes the pressure of the oil cylinder when performing seat test;PS-denotes the pressure of the oil cylinder when performing shell test
Valve shell test pressure=Valve nominal pressure×1.5; Valve seat test pressure=Valve nominal pressure×1.1
Welcome to our website! Please send your words at any time in the following form and ask us, we will contact you and provide you with the corresponding service as soon as possible. Please write in English.
Model:YFS-DL2400 Series
Testing Range:DN1400-2400,maximally test butterfly valves DN2400,1.0MPa
Testing Medium:Water,Air or Oil
Model: YFS-ZC Series
Testing Range: DN15-1000 (1/2”-40”) flanged end straight valves
Testing Medium: Water or Air(Gas)
Model:YFS-DL750 Series
Testing Range:DN350-750,maximally test butterfly valves DN750,2.5MPa
Testing Medium:Water,Air or Oil